Circular Prestressing
The circumferential prestressing resists the hoop tension generated due to the internal pressure. The prestressing is done by wires or tendons placed spirally, or over sectors of the circumference of the member. The wires or tendons lay outside the concrete core. Hence, the centre of the prestressing steel (CGS) is outside the core concrete section.
When the prestressed members are curved, in the direction of prestressing, the prestressing is called circular prestressing. For example, circumferential prestressing in pipes, tanks, silos, containment structures and similar structures is a type of circular prestressing. In these structures, there can be prestressing in the longitudinal direction (parallel to axis) as well. Circular prestressing is also applied in domes and shells.